Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Esp Cardiol (Engl Ed) ; 77(1): 39-49, 2024 Jan.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37217134

RESUMEN

INTRODUCTION AND OBJECTIVES: We aimed to describe the clinical outcomes of the use of the CentriMag acute circulatory support system as a bridge to emergency heart transplantation (HTx). METHODS: We conducted a descriptive analysis of the clinical outcomes of consecutive HTx candidates included in a multicenter retrospective registry who were treated with the CentriMag device, configured either for left ventricular support (LVS) or biventricular support (BVS). All patients were listed for high-priority HTx. The study assessed the period 2010 to 2020 and involved 16 transplant centers around Spain. We excluded patients treated with isolated right ventricular support or venoarterial extracorporeal membrane oxygenation without LVS. The primary endpoint was 1-year post-HTx survival. RESULTS: The study population comprised 213 emergency HTx candidates bridged on CentriMag LVS and 145 on CentriMag BVS. Overall, 303 (84.6%) patients received a transplant and 53 (14.8%) died without having an organ donor during the index hospitalization. Median time on the device was 15 days, with 66 (18.6%) patients being supported for> 30 days. One-year posttransplant survival was 77.6%. Univariable and multivariable analyses showed no statistically significant differences in pre- or post-HTx survival in patients managed with BVS vs LVS. Patients managed with BVS had higher rates of bleeding, need for transfusion, hemolysis and renal failure than patients managed with LVS, while the latter group showed a higher incidence of ischemic stroke. CONCLUSIONS: In a setting of candidate prioritization with short waiting list times, bridging to HTx with the CentriMag system was feasible and resulted in acceptable on-support and posttransplant outcomes.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Humanos , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/cirugía , Estudios Retrospectivos , Corazón Auxiliar/efectos adversos , Trasplante de Corazón/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
3.
J Am Coll Cardiol ; 82(9): 753-767, 2023 08 29.
Artículo en Inglés | MEDLINE | ID: mdl-37612006

RESUMEN

BACKGROUND: The reported prevalence of donor-transmitted coronary artery disease (TCAD) in heart transplantation (HT) is variable, and its prognostic impact remains unclear. OBJECTIVES: The goal of this study was to characterize TCAD in a contemporary multicentric cohort and to study its prognostic relevance. METHODS: This was a retrospective study of consecutive patients >18 years old who underwent HT in 11 Spanish centers from 2008 to 2018. Only patients with a coronary angiography (c-angio) within the first 3 months after HT were studied. Significant TCAD (s-TCAD) was defined as any stenosis ≥50% in epicardial coronary arteries, and nonsignificant TCAD (ns-TCAD) as stenosis <50%. Clinical outcomes were assessed by means of Cox regression and competing risks regression. Patients were followed-up for a median period of 6.3 years after c-angio. RESULTS: From a cohort of 1,918 patients, 937 underwent c-angio. TCAD was found in 172 patients (18.3%): s-TCAD in 65 (6.9%) and ns-TCAD in 107 (11.4%). Multivariable Cox regression analysis did not show a statistically significant association between s-TCAD and all-cause mortality (adjusted HR: 1.44; 95% CI: 0.89-2.35; P = 0.141); however, it was an independent predictor of cardiovascular mortality (adjusted HR: 2.25; 95% CI: 1.20-4.19; P = 0.011) and the combined event cardiovascular death or nonfatal MACE (adjusted HR: 2.42; 95% CI: 1.52-3.85; P < 0.001). No statistically significant impact of ns-TCAD on clinical outcomes was detected. The results were similar when reassessed by means of competing risks regression. CONCLUSIONS: TCAD was not associated with reduced survival in patients alive and well enough to undergo post-HT angiography within the first 3 months; however, s-TCAD patients showed increased risk of cardiovascular death and MACE.


Asunto(s)
Enfermedad de la Arteria Coronaria , Trasplante de Corazón , Humanos , Adolescente , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/cirugía , Constricción Patológica , Prevalencia , Pronóstico , Estudios Retrospectivos , Angiografía Coronaria , Trasplante de Corazón/efectos adversos
4.
Front Cell Infect Microbiol ; 13: 1165236, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37180450

RESUMEN

COVID-19-associated pulmonary aspergillosis (CAPA) has emerged as a frequent complication in the intensive care unit (ICU). However, little is known about this life-threatening fungal superinfection in solid organ transplant recipients (SOTRs), including whether targeted anti-mold prophylaxis might be justified in this immunosuppressed population. We performed a multicentric observational retrospective study of all consecutive ICU-admitted COVID-19 SOTRs between August 1, 2020 and December 31, 2021. SOTRs receiving antifungal prophylaxis with nebulized amphotericin-B were compared with those without prophylaxis. CAPA was defined according the ECMM/ISHAM criteria. Sixty-four SOTRs were admitted to ICU for COVID-19 during the study period. One patient received antifungal prophylaxis with isavuconazole and was excluded from the analysis. Of the remaining 63 SOTRs, nineteen (30.2%) received anti-mold prophylaxis with nebulized amphotericin-B. Ten SOTRs who did not receive prophylaxis developed pulmonary mold infections (nine CAPA and one mucormycosis) compared with one who received nebulized amphotericin-B (22.7% vs 5.3%; risk ratio 0.23; 95%CI 0.032-1.68), but with no differences in survival. No severe adverse events related to nebulized amphotericin-B were recorded. SOTRs admitted to ICU with COVID-19 are at high risk for CAPA. However, nebulized amphotericin-B is safe and might reduce the incidence of CAPA in this high-risk population. A randomized clinical trial to confirm these findings is warranted.


Asunto(s)
COVID-19 , Trasplante de Órganos , Humanos , Anfotericina B/uso terapéutico , Antifúngicos/uso terapéutico , Estudios Retrospectivos
5.
J Heart Lung Transplant ; 42(4): 488-502, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36470772

RESUMEN

BACKGROUND: We aimed to describe recent trends in the use and outcomes of temporary mechanical circulatory support (MCS) as a bridge to heart transplantation (HTx) in Spain. METHODS: Retrospective case-by-case analysis of 1,036 patients listed for emergency HTx while on temporary MCS in 16 Spanish institutions from January 1st, 2010 to December 31st, 2020. Patients were classified in 3 eras according to changes in donor allocation criteria (Era 1: January 2010/May 2014; Era 2: June 2014/May 2017; Era 3: June 2017/December 2020). RESULTS: Over time, the proportion of candidates listed with intra-aortic balloon pumps decreased (Era 1 = 55.9%, Era 2 = 32%, Era 3 = 0.9%; p < 0.001), while the proportion of candidates listed with surgical continuous-flow temporary VADs (Era 1 = 10.6%, Era 2 = 32%, Era 3 = 49.1%; p < 0.001) and percutaneous VADs (Era 1 = 0.3%, Era 2 = 6.3%; Era 3 = 17.2%; p < 0.001) increased. Rates of HTx increased from Era 1 (79.4%) to Era 2 (87.8%), and Era 3 (87%) (p = 0.004), while rates of death before HTx decreased (Era 1 = 17.7%; Era 2 = 11%, Era 3 = 12.4%; p = 0.037) Median time from listing to HTx increased in patients supported with intra-aortic balloon pumps (Era 1 = 8 days, Era 2 = 15 days; p < 0.001) but remained stable in other candidates (Era 1 = 6 days; Era 2 = 5 days; Era 3 = 6 days; p = 0.134). One-year post-transplant survival was 71.4% in Era 1, 79.3% in Era 2, and 76.5% in Era 3 (p = 0.112). Preoperative bridging with ECMO was associated with increased 1-year post-transplant mortality (adjusted HR=1.71; 95% CI 1.15-2.53; p = 0.008). CONCLUSIONS: During the period 2010 to 2020, successive changes in the Spanish organ allocation protocol were followed by a significant increase of the rate of HTx and a significant reduction of waiting list mortality in candidates supported with temporary MCS. One-year post-transplant survival rates remained acceptable.


Asunto(s)
Terapia Puente , Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Humanos , Oxigenación por Membrana Extracorpórea/métodos , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/terapia , Trasplante de Corazón/métodos , Estudios Retrospectivos , España/epidemiología , Resultado del Tratamiento , Listas de Espera , Terapia Puente/métodos , Terapia Puente/tendencias , Obtención de Tejidos y Órganos/métodos , Obtención de Tejidos y Órganos/tendencias
6.
Rev Esp Cardiol (Engl Ed) ; 76(4): 227-237, 2023 Apr.
Artículo en Inglés, Español | MEDLINE | ID: mdl-36055642

RESUMEN

INTRODUCTION AND OBJECTIVES: This report presents the clinical characteristics, outcomes and complications of all consecutive patients implanted with a long-term mechanical circulatory support device in Spain between 2007 and 2020. METHODS: Analysis of the Spanish Registry of durable ventricular assist devices (REGALAD) including data form Spanish centers with a mechanical circulatory support program. RESULTS: During the study period, 263 ventricular assist devices were implanted in 22 hospitals. The implanted device was an isolated continuous-flow left ventricular assist device in 182 patients (69%), a pulsatile-flow device (58 isolated left ventricular and 21 biventricular) in 79 (30%), and a total artificial heart in 2 patients (1%). The strategy of the implant was as bridge to heart transplant in 78 patients (30%), bridge to candidacy in 110 (42%), bridge to recovery in 3 (1%) and destination therapy in 72 patients (27%). Overall survival at 6, 12 and 24 months was 79%, 74% and 69%, respectively, and was better in continuous-flow left ventricular assist devices (84%, 80%, and 75%). The main adverse events related to this therapy were infections (37% of patients), bleeding (35%), neurological (29%), and device malfunction (17%). CONCLUSIONS: Durable ventricular assist devices have emerged in Spain in the last few years as a useful therapy for patients with advanced heart failure. As in other international registries, the current trend is to use continuous-flow intracorporeal left ventricular devices, which are associated with better results. Adverse events continue to be frequent and severe.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Humanos , España/epidemiología , Resultado del Tratamiento , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Sistema de Registros , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...